NEW YORK STATE CLASS AB UST

CAREER EXAMS
Loading...

Loading study material viewer...

Page 0 of 0

Document Text

  • | Page

NEW YORK STATE CLASS A/B UST

OPERATOR EXAM QUESTI ONS

WITH CORRECT ANSWER S

Question : Does New York State DEC Class A/B UST

Operator certification expire?CORRECT ANSWER : NO: A/B certification does not expire unless revoked by DEC due to significant noncompliance with regulatory requirements (2-4)

Question : UST financial responsibility requirements

apply to what?

CORRECT ANSWER : All petroleum dispensing/UST

facilities, with a minimum of $500,000 responsibility per occurrence (5-2)

Question : Secondary Containment is required for what?

CORRECT ANSWER : Category 3 UST Systems,

Category 3 piping in contact with the ground, and Replacement UST/Piping (9-2, 10-1)

  • | Page

Question : A Class A operator shall maintain the records

of UST site inspections for a minimum of:

CORRECT ANSWER : 3 years (15-4, 15-5)

Question : New owners of an existing UST system shall

register the UST system with NYS DEC within what period from date of ownership?

CORRECT ANSWER : 30 days (4-5)

Question : UST systems with cathodic protection should

be inspected for proper operation by a qualified cathodic

protection tester on the following schedule:

CORRECT ANSWER : Yearly (11-4)

Question : UST systems with impressed current cathodic

protection systems and rectifiers must be inspected at a

minimum:

CORRECT ANSWER : every 60 days (11-4)

  • | Page

Question : Within what period after a repair should a

cathodically protected UST system be tested to ensure it is working properly?

CORRECT ANSWER : 6 months (11-6)

Question : Pressurized underground piping that routinely

contains regulated substances shall be monitored for releases in a manner that meets what requirements?

CORRECT ANSWER : Be equipped with a line leak

detector with an annual line tightness test, and practice weekly interstitial monitoring of the tank top sump (electronic or manual) (10-3)

Question : A suspected release must be confirmed to the

NYS DEC within:

CORRECT ANSWER : 7 days (14-7)

Question : You must report a known spill to NYSDEC

within 2 hours of discovery UNLESS:

CORRECT ANSWER : The spill is less than 5 gallons in

volume, is contained and under control, has not and will

  • | Page

not reach the State's land or waters, and is cleaned up within 2 hours of discovery (14-4)

Question : To permanently close a tank, an owner and

operator shall:

CORRECT ANSWER : Empty and clean the tank by

removing all liquids and accumulated sludge, remove the tank from the ground OR fill all voids within with an inert solid material, disconnect and remove all piping, vent lines, and ancillary equipment, ensure that all scheduled deliveries to the tank are terminated (6-2)

Question : If you have 100 or fewer tanks, financial

responsibility is required in the aggregate the amount of:

CORRECT ANSWER : $1,000,000 (5-2)

Question : Petroleum marketers are required to have

financial responsibility to cover X dollars per occurrence.X is....

CORRECT ANSWER : $1,000,000 (5-2)

Download Study Material

Buy This Study Material

$30.00
Buy Now
  • Immediate download after payment
  • Available in the pdf format
  • 100% satisfaction guarantee

Study Material Information

Category: CAREER EXAMS
Description:

NEW YORK STATE CLASS A/B UST OPERATOR EXAM QUESTI ONS WITH CORRECT ANSWER S Question : Does New York State DEC Class A/B UST Operator certification expire? CORRECT ANSWER : NO: A/B certification do...

Purchase PDF $30.00