Question :1) The total rating of a cord and plug connected

room air conditioner must not exceed ______ of the rating of a branch circuit where lighting outlets, other appliances, or general use receptacles are also supplied (a) 75% (b) 50% (c) 100% (d) 80%

Correct answer:b. 50%

Question :2) Except for storable pools, fixed or stationary

equipment other than an underwater luminaire cord must not

exceed ____ in length:

(a) 4.5 ft (b) 2.5 ft (c) 5 ft (d) 3 ft

Correct answer:d. 3 ft

Question :3) Receptacles located more than _____ above the

floor are not required to be tamper resistant:

(a) 4.5 ft

(b) 5.5 ft (c) 4 ft (d) 6 ft

Correct answer:b. 5.5 ft

Question :4) The feeder circuit for a mobile or a mobile or

manufactured home must be rated at not less than ____ at

120/240V

(a) 100 A (b) 50 A (c) 75 A (d) 200 A

Correct answer:a. 100 A

Question :5) ______ circuit breakers or sets of fuses are

acceptable as over current device to provide overload

protection in one family dwellings:

(a) 2 to 6 (b) 2 to 12 (c) 4 to 6 (d) 4 to 12

Correct answer:a. 2 to 6

Question :6) At least _____ of free conductor, measured from

the point in the box where it emerges from its raceway or

cable sheath shall be left at each outlet, junction and switch

point:

(a) 5 in (b) 4 in (c) 6 in (d) 3 in

Correct answer:c. 6 in

Question :7) Splices and taps must be accessible and must

not fill raceway to more than _____ of its cross-sectional

area:

(a) 100% (b) 80% (c) 75% (d) 50%

Correct answer:c. 75%

Question :8) A two pole circuit breaker or fusible switch

shall be considered as _____ over current devices:

(a) One (b) Two (c) Four (d) Three

Correct answer:b. Two

Question :9) _____ is the maximum approved electrical trade

size for PVC conduit:

(a) 6 in (b) 0.5 in (c) 2 in (d) 4 in

Correct answer:a. 6 in

Question :10) The overhead service conductors above a roof

with a slope of at least 4.in in 12.in have a minimum

clearance of ______:

(a) 5 ft (b) 2.5 ft (c) 4 ft (d) 3 ft

Correct answer:d. 3 ft

Question :11) A switch or circuit breaker enclosure may be

used as a raceway if the conductor fill doesnot exceed _____

:

(a) 40% (b) 80% (c) 75% (d) 50%

Correct answer:a. 40%

Download Study Material

Buy This Study Material

$30.00
Buy Now
  • Immediate download after payment
  • Available in the pdf format
  • 100% satisfaction guarantee

Study Material Information

Category: CAREER EXAMS
Description:

NEC PRACTICAL PRACTICE TEST (PART 2) QUESTIONS AND ANSWER S WITH SOLUTIONS Question :1) The total rating of a cord and plug connected room air conditioner must not exceed ______ of the rating of a ...

Purchase PDF $30.00
Gaviki.com is an independent educational platform providing practice exams and study resources. Our materials are developed through independent research by our education team. We are not affiliated with, authorized by, or endorsed by any official exam testing facilities, certification boards, or exam sponsors. Any trademarks or exam names mentioned are for identification purposes only.