Level 1 Water Distribution Practice Test

Study Guides
Loading...

Loading study material viewer...

Page 0 of 0

Document Text

Level 1 Water Distribution Practice Test Questions and Answers 100% Correct

Question : The minimum and maximum chloride residual in a

water distribution system is ?

Correct answer: 0.2 mg/l and 4mg/L of free chlorine

Question : Nitrate may not exceed what concentration when

tested yearly for a groundwater treatment plant ?

Correct answer: 10 mg/L

Question : The minimum number of total coliform samples

that must be collected per month is based on Wich of the following ?

Correct answer: The population served by the system

Question : When a distribution bacteriological sample is

positive for a total coliform the procedure is ?

Correct answer: Repeat the sample and take a sample 5

connections upstream and downstream to confirm total coliform

Question : For lead and copper sample the water must be In

the pipeline for at least?

Correct answer: 6 hours

Question : What is hydraulic grade line ?

Correct answer: A line to which the water level would rise in

a small ,vertical tube,connected to the pipe

Question : How often should cathodic protection anodes in

your system be inspected?

Correct answer: Every year

Question : Water pipelines are generally designed to carry

water at a velocity below ?

Correct answer: 2.5b FPS. Feet per second

Question : Energy use in water systems is defined best by ?

Correct answer: Energy use varies among systems and an

energy inventory study would need to be conducted to determine relationships

Question : The minimum recommended separation distance

between a water main and a storm sewer is ?

Correct answer: 6 feet

Question : Which of the following should be in an

organization plan ?

Correct answer: Identifies clear lines ,defines the divisions of

labor ,establishes unity of command

Question : If pipelines are not restrained using steel rods

concrete thrust blocks can be used at ?

Correct answer: Every bend and transition

Question : Engineering Drawings that show the depth of pipe,

the pipe location both vertically and horizontally and the correct distance form a reference point are known as which of the following

Correct answer: Plan and profile drawings

Question : Which are the components of directing staff ?

Correct answer: Motivating & communicating

Question : The accuracy of large meters should fall within

what range ?

Correct answer: Not less than 97% not more than 103%

Question : In some older water system lead service line still

exist. What would be the best practice when finding lead pipe ?

Correct answer: Be replaced

Question : What is the acceptable range for water loss in a

typical municipal distribution system that has a variety of pvc and di pipe ?

Correct answer: 20% (80% effienciency)

Download Study Material

Buy This Study Material

$30.00
Buy Now
  • Immediate download after payment
  • Available in the pdf format
  • 100% satisfaction guarantee

Study Material Information

Category: Study Guides
Description:

Level 1 Water Distribution Practice Test Questions and Answers 100% Correct Question : The minimum and maximum chloride residual in a water distribution system is ? Correct answer: 0.2 mg/l and 4mg...

Purchase PDF $30.00
Gaviki.com is an independent educational platform providing practice exams and study resources. Our materials are developed through independent research by our education team. We are not affiliated with, authorized by, or endorsed by any official exam testing facilities, certification boards, or exam sponsors. Any trademarks or exam names mentioned are for identification purposes only.