Question 1: Xrays are used in CT because:

  • they are easily produced by the high frequency generator
  • they are less harmful than the heating effects of microwave radiation
  • they penetrate the body according to specific attenuation characteristics of each tissue
  • the FDA imposes no limit on the dose to the patient

Correct Answer: C

Question 2: Most of the commands from the technologists are received by the:

  • array processor
  • host computer
  • operators console
  • gantry

Correct Answer: C) operators console

  • | P a g e

Question 3: Xrays are produced whenever fast moving electrons collide with any form of matter

because:

  • The electron loses kinetic energy which is converted into the emission of an x-ray photon
  • The electron absorbs thermal energy and reflects it as a photon
  • The matter converts its potential energy into radiation
  • The collision generates an electrical charge within the detector
  • Correct Answer: A) The electron loses kinetic energy which is converted into the emission of an x-ray photon

Question 4: The mA determines the:

  • quality of x-ray photons
  • quantity of x-ray photons
  • spatial resolution of the image
  • speed of the tube rotation

Correct Answer: B) quantity of x-ray photons

Question 5: Which of the following is a component NOT normally located in the gantry of a modern CT system?

  • x-ray tube
  • slip rings
  • array processor
  • solid-state detectors

Correct Answer: C) array processor

Question 6: Tube interscan delay time refers to:

  • the time required for the patient table to move into position
  • | P a g e
  • the time between the end of one scan and the start of the next scan during which the tube will
  • cool

  • the time it takes for the array processor to reconstruct the image
  • the delay before contrast media is injected
  • Correct Answer: B) the time between the end of one scan and the start of the next scan during which the tube will cool

Question 7: Increased _______ will increase the likelihood that a given x-ray will penetrate a material.

  • kV
  • mA
  • exposure time
  • pitch

Correct Answer: A) kV

Question 8: Which of the following are NOT commonly used on today's commercially available CT scanners? 1. xenon detectors 2. fourth-generation technology 3. continuous rotation technology

  • 1 only
  • 1 and 2
  • 2 and 3
  • 1, 2, and 3

Correct Answer: B) 1 and 2

Question 9: Which of the following statements is FALSE regarding occurrences after an x-ray photon penetrates the detector aperture?

  • the photon can pass through the detector unmeasured
  • the photon is converted completely into an electron
  • | P a g e
  • the measured signal is enhanced by an amplifier
  • the photon can be absorbed by the detector material

Correct Answer: B) the photon is converted completely into an electron

Question 10: Scatter radiation is caused by:

  • inadequate cooling of the x-ray tube
  • deflections from the original trajectory of an x-ray photon through the patient
  • electrical interference in the array processor
  • improper calibration of the solid-state detectors
  • Correct Answer: B) deflections from the original trajectory of an x-ray photon through the patient

Question 11: What control does the operator have over the x-rays in a CT exam?

  • the energy level and the quantity of x-rays can be selected
  • the speed of the x-ray photons can be altered
  • the direction of the scatter radiation can be focused
  • the operator has no control over the x-ray production

Correct Answer: A) the energy level and the quantity of x-rays can be selected

Question 12: Which of the following is the standard that's used to achieve compatibility for image transfer between various imaging modalities, viewing stations, and printers in a hospital?

A) PACS

B) RIS

C) DICOM

D) HIS

Correct Answer: C) DICOM

Download Study Material

Buy This Study Material

$30.00
Buy Now
  • Immediate download after payment
  • Available in the pdf format
  • 100% satisfaction guarantee

Study Material Information

Category: CAREER EXAMS
Description:

CT REGISTRY LATEST REVIEW WITH COMPLETE SOLUTION COMPLETE AND VERIFIED STUDY MATERIAL Question 1: Xrays are used in CT because: A) they are easily produced by the high frequency generator B) they a...

Purchase PDF $30.00
Gaviki.com is an independent educational platform providing practice exams and study resources. Our materials are developed through independent research by our education team. We are not affiliated with, authorized by, or endorsed by any official exam testing facilities, certification boards, or exam sponsors. Any trademarks or exam names mentioned are for identification purposes only.